New mesh shape and improved implantation procedure to simplify and standardize open ventral hernia repair: a preliminary report.
2010
Introduction Issues in ventral hernia repair are represented by the need for mesh fixation and how to assure a sufficient mesh overlap of the defect. Aiming to resolve these problems, this study describes a modified technique for ventral and incisional hernia repair based upon a newly developed mesh with a special design. This new type of implant allows broader coverage of the abdominal wall and results in tension- and fixation-free repair. Materials and methods A unique geometrically shaped mesh consisting of a large central body and radiating arms was used to repair ventral or incisional hernia. The mesh was intended not to be point-fixated. The friction of the straps passing through the …
Fixation-free incisional hernia repair in the elderly: our experience with a tentacle-shaped implant.
2016
Background: Incisional hernia in aged patients represents a challenge even for experienced surgeons. Besides increased risk of complications due to comorbidities, mesh fixation and assuring a sufficient mesh overlap of the defect are the main issues in carrying out the repair. Aims: In order to assure broader coverage of the abdominal wall and a tension- and fixation-free repair, a specifically designed prosthesis was developed for the surgical treatment of incisional hernias. The results of a fixation-free incisional hernia repair carried out in elderly patients using a tentacle-shaped implant are reported herewith. Methods: A tentacle-shaped flat mesh with a large central body and integra…
Prosthetic strap system for simplified ventral hernia repair. Its results in a porcine experimental model.
2010
Abstract: Introduction Aiming to achieve a simplified ventral hernia repair, a proprietary shaped mesh was experimentally tested in the porcine model. The mesh is structured with a large central body and radiating straps. The friction of the straps passing through the tissues are hypothesized to be adequate to maintain the mesh in place during tissue ingrowth, avoiding classic point fixation while ensuring a wide coverage of the abdomen. Methods The mesh, having 6 radial straps, was placed using a sublay preperitoneal technique in 4 pigs. All straps were passed laterally through the abdominal wall and exteriorized from the skin. The straps were trimmed at the level of the skin, allowing the…
The use of a new kind of low profile retractor for arteriovenous fistula procedure simplifies and speeds up the intervention
2009
Purpose The aim of this study was to demonstrate the effectiveness of a new kind of disposable surgical retractor in arteriovenous fistula (AVF) procedures in order to achieve an easier, faster and safer surgical intervention. Methods Between January and June 2008, 22 AVF procedures were performed using the 3PAWS ReeTrakttrade; (Insightra Inc. - Irvine, Ca., USA) a self-retaining, low profile retractor. An equivalent patient sample, in which an AVF was performed using conventional retraction devices, was considered for comparison of the intra- and post-operative results. Results In all of the 22 AVF procedures performed, the ReeTrakt™ system has simplified the performance of the surgical te…